Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
Ptac wall sleeve installation instructions.
Prepare and install the new wall sleeve according to the instructions below.
The wall sleeve must be fastened securely before installing the air conditioner unit.
The wall sleeve be installed a minimum of 36 from the ceiling.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
When you visit any website it may store or retrieve information on your browser mostly in the form of cookies.
The sleeve will fit flush in the wall extending outside the structure.
To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
Wall case must be sealed caulked to outside wall on all four 4 sides.
The air conditioner will slide into the sleeve but is not flush with the wall.
Page 3 pre installation considerations before proceeding with the sleeve installation ensure the following guidelines for locating the wall opening and sleeve are met.
This information might be about you your preferences or your device and is mostly used to make the site work as you expect it to.
See the drain kit for internal actual installation instructions.
Standard steel wall cases are 42 w 16 h 13 3 4 d.
All wall and window wall installations must provide for proper drainage.
All wall and window wall installations must provide for proper drainage.
Failure to install and maintain our product according to these instructions may void any product warranty.
While the dimensions may appear to be incompatible the 2 devices should fit properly.
16 24 28 and 31 deep cases are available for thicker walls.
For new installs ensure the wall is properly framed to support the weight and dimensions of the wall sleeve and air conditioner.
There is a portion of the air conditioner which extends a few inches back into the room.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
Tools required by.
Installation guidelines for sealing ptac sleeves read these instructions completely before starting any installation.
For sunrooms and modular buildings adhere to their installation instructions for supporting and sealing sleeve to their frames.
Wall case should be sealed caulked to the inside wall on all four 4 sides.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
When a drain kit is to be installed do so before top of wall sleeve installing the wall sleeve in the wall.